Blog

F-Gas Phase Down 2027 UK: What Retail Estates Need to Know

On 1 January 2027, the amount of hydrofluorocarbon (HFC) refrigerant that can be placed on the market in Great Britain falls again. For a property or estates director running a grocery, hospitality or food service estate, that date deserves a place in the capital plan now. It arrives before most replacement programmes are finished, and it affects what every remaining HFC system will cost to keep running.

F-Gas Phase Down 2027 UK: What Retail Estates Need to Know
22 October 2026

The step is not new. It has been written into the GB F-gas Regulation for years. What changed in 2026 is that the government confirmed it will apply exactly as written. Defra consulted on a steeper cut, then said in May 2026 that it would not legislate in 2026 to change the phase-down steps from 1 January 2027. The existing schedule therefore stands.

This article explains the F-gas phase down for 2027 in the UK in plain English, what it means for estates still running HFC refrigeration, and what estate teams can do in the weeks before January.

What Changes on 1 January 2027

The GB F-gas Regulation limits the HFCs that producers and importers can place on the market each year. The limit is a quota measured in tonnes of carbon dioxide equivalent (CO2e), set as a percentage of a baseline. In Great Britain, that baseline is the annual average placed on the market between 2015 and 2019.

The schedule sits in Annex V of the regulation (often called Annex 5). For 2024 to 2026 the quota is 31% of baseline. From 1 January 2027 it falls to 24%, where it stays until the end of 2029. In 2030 it falls again, to 21%.

Seven percentage points can sound modest. It is not. As FETA (the Federation of Environmental Trade Associations, which represents the UK heating, ventilation, air conditioning and refrigeration industry) points out, moving from 31% to 24% is a 22.6% drop in refrigerant availability compared with today.

Because the quota is counted in CO2e rather than kilograms, high global warming potential (GWP) gases use it up fastest. R404A, still found in older commercial refrigeration, has a GWP of 3,922. Every kilogram of it consumes far more quota than the same mass of a lower-GWP alternative.

Why the step was not changed. Defra consulted between November and December 2025 on going further than the current schedule. After assessing 137 responses, it concluded that “further work is required” and confirmed the Annex 5 step will apply for 2027. Defra has said it remains committed to reform and intends to publish a summary of responses and next steps later in 2026. At the time of writing, that report has not appeared. FETA’s view, reported by Cooling Post, is that the delay “may have postponed a major regulatory change, but the direction of travel remains unchanged.”

Northern Ireland is different. Northern Ireland remains in the EU F-gas system and follows Regulation (EU) 2024/573. Its 2027 step is steeper. Annex VII of the EU regulation cuts the maximum quantity of HFCs placed on the EU market from 42,874,410 tonnes CO2e in 2025 to 2026 to 21,665,691 tonnes CO2e for 2027 to 2029, roughly halving it. Businesses moving refrigerant between Great Britain and Northern Ireland also need the right quota on each side.

Where Rule 2026 From 1 January 2027 Change in supply
Great Britain GB F-gas Regulation, Annex V 31% of baseline 24% of baseline About 22.6% less
Northern Ireland Regulation (EU) 2024/573, Annex VII 42.9 million t CO2e (EU-wide) 21.7 million t CO2e (EU-wide) About 49% less

What It Means for Retail Estates

The quota cut is placed on producers and importers, not on retailers. But estates feel it through three routes.

Cost. Less supply tends to mean higher prices. Defra’s own 2022 assessment of the GB regulation said the supply constraint caused by the phase-down “was expected to increase HFC prices”, and that the phase-down “has increasingly restricted availability and accessibility of HFCs”. The analysis behind it predicted an average increase of £5 to £12 per kilogram for refrigerant gases, with a total annual cost of £40 to £100 million in 2030.

Nobody can say precisely how GB prices will move in January. EU price monitoring by the independent consultancies Öko-Recherche and CITEPA shows why. In the fourth quarter of 2025, EU prices for common HFCs were broadly stable and no shortages were reported. Yet R134a still cost between 3.7 and 9.5 times its 2014 level, depending on where in the supply chain it was bought. The pattern suggests that each quota cut raises the price floor over time, even when short-term prices look calm.

Availability for servicing. In Great Britain, virgin F-gas with a GWP above 2,500 has been banned since 2020 for refilling refrigeration systems holding 40 tonnes CO2e or more. For R404A, that threshold is just 10.2 kg. Reclaimed or recycled gas can still be used, but only until 2030. In the EU, reclaimed R404A was priced at 140% of virgin material in early 2025. A shrinking quota adds pressure to an already narrow route for keeping older systems running.

Replacement pressure. Defra’s assessment notes that much of commercial refrigeration has already moved away from high-GWP HFCs to alternatives such as CO2 and propane. The pressure sits with the long tail: older stores, acquired sites, cold rooms, cellar cooling and remote condensing units spread across many contractors. Every leak, failure or top-up on those systems now raises the same question. Repair, retrofill or replace?

The problem for an estates director is rarely a lack of options. It is deciding which systems to deal with first when the budget will not cover all of them, and showing finance why that order is right.

Before January: A Practical Checklist

Most of the work that makes 1 January 2027 manageable can start now, without new budget.

  1. Build a refrigerant register you trust. For every system, record the site, refrigerant type, charge in kilograms and tonnes CO2e, age and recent top-ups. Flag gases with a GWP above 2,500 and systems at or above 40 tonnes CO2e. Your F-gas service and leak check records are a good starting point.
  2. Spot struggling systems early. Look for cases that fail to hold temperature, compressors running longer than comparable plant, repeated alarms and repeat call-outs. These are often the first signs that a system is costing more than it should, and a fix made before January avoids buying gas at a higher price.
  3. Rank replacements by real performance, not age alone. Two systems installed in the same year can behave very differently. Combine refrigerant type and charge with how each system actually performs, its maintenance history and the commercial risk at that site, such as stock value and food safety.
  4. Talk to contractors and suppliers now. Ask about gas availability and pricing terms for 2027, reclaimed gas, retrofill options and lead times for new plant. Agree how top-ups will be approved once prices change.
  5. Build the evidence finance will ask for. For each priority system, set out current maintenance and top-up costs, its exposure to refrigerant prices, its operating performance and the cost of waiting until 2030. A ranked programme with evidence behind each line is easier to approve than a list sorted by install date.
  6. Plan beyond 2027. The quota falls again in 2030, reclaimed high-GWP gas for servicing ends in 2030, and Defra still intends to reform the phase-down. A plan that only works for next year will need rewriting soon.
  7. Treat Northern Ireland sites separately. They sit under EU rules with a steeper 2027 step, so check supply and pricing with suppliers serving that market.

What a trusted register looks like: charge and tonnes CO2e by refrigerant in Conex Refrigerant, part of Conex OS. Demo data.

Where Conex OS Helps

Steps one, two, three and five on the checklist depend on two things: a complete record of the refrigerant in every system, and reliable operating data from those systems, held in one place. Both are hard when each contractor keeps its own logbook and each store runs a different controller.

Conex Refrigerant, part of Conex OS, is the estate’s refrigerant register. Engineers log every top-up, recovery and repair against the asset on site, from their phone, and the estate gets one live view of refrigerant type, charge, tonnes CO2e, leak rate and checks due.

The Conex Refrigerant estate overview: leak rate, refrigerant added, installed charge and checks needing action across every site. Demo data.

For each system it calculates the tonnes CO2e, sets the leak check interval that applies at the 5, 50 and 500 tonne CO2e thresholds, and tracks every due date in one compliance calendar, with the rule cited against each action. Because gas type, GWP and charge sit against every asset, it is easy to see which systems the servicing ban affects, and an audit-ready report of the estate’s F-gas position is available on request. It needs no new hardware to start, and contractor engineers log for free.

The compliance calendar: every check and repair due, filterable by site, region, maintainer and regulation. Demo data.

That register also answers the questions January raises. Which systems hold the most CO2e? Which leak the most, and how much refrigerant has the estate added this year? With every top-up logged against its asset, chronic leakers show up in the data rather than in the gas bill, and refrigerant leakage can be reported as measured Scope 1 emissions rather than an estimate.

Conex Insight adds the operating picture. It brings refrigeration data from existing controllers and building management systems across the estate into one standardised view, so teams can see which systems are struggling to hold temperature, alarming repeatedly or behaving differently from comparable assets, without waiting for a store to report a problem. Where stores are connected, Conex Refrigerant runs leak rules on that live data and logs any alert against the asset record, so a probable leak can be spotted between periodic checks rather than at the next top-up. Iris, the Conex AI assistant, then shows which assets have triggered a leak rule over the last day, three days or week.

Asset Performance Scoring, part of Conex Insight, ranks assets using operational data such as the ability to maintain expected conditions, alarm frequency, repeated fault patterns, runtime and maintenance activity. Scores run from 1 to 10, where 1 means good performance and 10 means poor performance, so the assets at the top of the list are those with the strongest evidence for intervention. Combined with the refrigerant type, charge and leak history held in Conex Refrigerant, this supports a replacement list ranked by performance and exposure rather than age alone.

Dashboards and reporting then turn that history into the evidence a capital plan needs: how each system has performed over time, how often it has needed attention, how much refrigerant it has lost, and how it compares with similar assets elsewhere in the estate. Conex OS supports these decisions and provides the records the F-gas rules ask for. It does not replace certified engineers, required leak checks or any leak detection system the regulation requires, and it does not by itself make an estate compliant.

The Bottom Line

The 1 January 2027 step is fixed. In Great Britain, refrigerant supply falls by about a fifth. Under the EU rules that apply in Northern Ireland, it roughly halves. Refrigerant will not disappear overnight, but HFC systems that leak, fail or underperform will cost more to keep running, and the case for replacing them will get stronger each year until 2030.

The estates that handle this best will not be the ones that replace the most plant. They will be the ones that know which systems are struggling, rank them on evidence and give finance a clear, defensible order of work.

If you would like to see how your refrigeration estate ranks on performance before January, the LoweConex team is happy to talk it through. Get in touch at www.loweconex.com/contact-us

Frequently Asked Questions

What changes in the F-gas phase down in 2027 in the UK?

From 1 January 2027, the HFC quota for Great Britain falls from 31% to 24% of the 2015 to 2019 baseline. It stays at 24% until the end of 2029, then falls to 21% in 2030. That is about 22.6% less refrigerant than is available today.

Has the 2027 step been delayed or changed?

No. Defra consulted on a steeper cut in late 2025, but said in May 2026 that it would not legislate in 2026 to change the phase-down steps from 1 January 2027. The schedule in Annex V of the GB F-gas Regulation applies as written.

Does the quota cut apply to retailers?

Not directly. The quota is placed on producers and importers of HFCs. Retailers feel it through higher refrigerant costs, tighter options for servicing older systems and growing pressure to replace them.

Will refrigerant prices rise in 2027?

Nobody can say precisely. Defra’s 2022 assessment expected the phase-down to increase HFC prices, with its analysis projecting an average rise of £5 to £12 per kilogram. EU monitoring shows prices can look stable in the short term while staying far above their 2014 level.

Can we still top up R404A systems?

For larger systems, only with reclaimed or recycled gas, and only until 2030. Since 2020, virgin F-gas with a GWP above 2,500 has been banned for refilling refrigeration systems holding 40 tonnes CO2e or more. For R404A, that threshold is a charge of just 10.2 kg.

What about sites in Northern Ireland?

Northern Ireland follows the EU F-gas Regulation, and its 2027 step is steeper. The EU-wide maximum falls from about 42.9 million to 21.7 million tonnes CO2e for 2027 to 2029, roughly halving supply. Check supply and pricing with suppliers serving that market.

How should we decide which systems to replace first?

Rank systems on evidence rather than age alone. Combine refrigerant type and charge with how each system actually performs, its maintenance history and the commercial risk at that site, such as stock value and food safety. That gives finance a clear, defensible order of work.